Generac Commercial Series 100kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant

Generac Commercial Series 100kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant
Our Price
Compare Prices
Shipping Info
Model: QT10068GNAC
No RatingNo RatingNo RatingNo RatingNo Rating
Number of Reviews (0)
Write A Review
$25,097.00
$314 / Month
With our 132 months 9.99% APR*
132 fixed monthly payments required.
Factory-Direct
This Item Is Built To Order
Factory items ship direct from the manufacturer.
Shipping times vary.
Shipping Crate Icon
Free Shipping
Voltage
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
 
Free Shipping$25,097.00Buy Now
Free Freight$25,097.00Visit Site
Factory-Direct
This Item Is Built To Order
Free Freight
Free Freight
*We currently CANNOT ship this product to Alaska, Hawaii or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • 2
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Grade
Style
Run Watts
94,000
Rated Watts
Voltage
120/208 Three-Phase
Fuel
Engine
Grade
Emergency
Style
Standby (Liquid Cooled)
Run Watts
94,000
Voltage
120/208 Three-Phase
Fuel
Natural Gas
Engine
Generac 6.8 L V-10
Features
Features
  • SCAQMD Compliant
  • Meets emissions requirements for sale in CA/MA
  • Generac QT 100 Emergency Standby Generator
  • Designed for small commercial buildings
  • For 120/208 Volt Three-Phase applications
  • Natural Gas (NG) Powered
  • WILL NOT WORK with LP fuel source
  • Solid State, Frequency Compensated Voltage Regulation
  • Provides fast response to changing load conditions
  • Allows for digital voltage regulation of +/- 1%
  • 6.8L Generac V-10 Automotive-Style Engine
  • Brushless Alternator - Less Than .25 % THD
  • Improved frequency (HZ) regulation for cleaner power
  • Digital Nexus™ Controller
  • Two-Line, tri-lingual LCD display for ease of use
  • Provides service & maintenance intervals
  • Automatic Shutdown Safety Feature
  • High coolant temp, low coolant, low oil pressure and overspeed
  • Quiet-Test™ Mode
  • Low-speed exercise mode for quieter weekly tests; 68 dB @ 23'
  • Sound Attenuated, Acoustically Designed Aluminum Enclosure
  • Corrosion-resistant material ideal for salty air conditions
  • Mobile Link (Sold Separately)
  • Easily check generator status via computer, tablet or smartphone
  • Transfer Switch (Sold Separately)
  • Customize your system based on your actual application
  • 2-Year Limited Warranty
  • ^Please Note - Requires Loading Dock, Forklift or Crane For Delivery^
Specifications
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Alternator
Brushless
Auto Voltage Regulation
Yes
Rated Watts
94000 Watts
Fuel Type
Natural Gas
NG Power Capacity
94000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
Rated Amps
326 Amps
Decibel Rating @ 7m Learn More
Decibel Rating @ 7m
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
68 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Battery
Not Included (700 CCA)
Enclosure
Aluminum
Circuit Breaker Size
400 Amps
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Engine
Engine Brand
Generac 6.8 L V-10
Starting System
12v Auto Start
CC
6800 CC
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Overview
Weight
2531 Pounds
Made in USA
Yes
Consumer Warranty
2 Years
Commercial Warranty
2 Years
Product Style
Standby Generator
Product Length
115.16 Inches
Product Width
36.81 Inches
Product Height
54.84 Inches
UPC
696471610178
Grade
Style
Run Watts
94,000
Rated Watts
Voltage
120/208 Three-Phase
Fuel
Engine
Grade
Emergency
Style
Standby (Liquid Cooled)
Run Watts
94,000
Voltage
120/208 Three-Phase
Fuel
Natural Gas
Engine
Generac 6.8 L V-10
Features
Features
  • SCAQMD Compliant
  • Meets emissions requirements for sale in CA/MA
  • Generac QT 100 Emergency Standby Generator
  • Designed for small commercial buildings
  • For 120/208 Volt Three-Phase applications
  • Natural Gas (NG) Powered
  • WILL NOT WORK with LP fuel source
  • Solid State, Frequency Compensated Voltage Regulation
  • Provides fast response to changing load conditions
  • Allows for digital voltage regulation of +/- 1%
  • 6.8L Generac V-10 Automotive-Style Engine
  • Brushless Alternator - Less Than .25 % THD
  • Improved frequency (HZ) regulation for cleaner power
  • Digital Nexus™ Controller
  • Two-Line, tri-lingual LCD display for ease of use
  • Provides service & maintenance intervals
  • Automatic Shutdown Safety Feature
  • High coolant temp, low coolant, low oil pressure and overspeed
  • Quiet-Test™ Mode
  • Low-speed exercise mode for quieter weekly tests; 68 dB @ 23'
  • Sound Attenuated, Acoustically Designed Aluminum Enclosure
  • Corrosion-resistant material ideal for salty air conditions
  • Mobile Link (Sold Separately)
  • Easily check generator status via computer, tablet or smartphone
  • Transfer Switch (Sold Separately)
  • Customize your system based on your actual application
  • 2-Year Limited Warranty
  • ^Please Note - Requires Loading Dock, Forklift or Crane For Delivery^
Specifications
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Alternator
Brushless
Auto Voltage Regulation
Yes
Rated Watts
94000 Watts
Fuel Type
Natural Gas
NG Power Capacity
94000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
Rated Amps
326 Amps
Decibel Rating @ 7m Learn More
Decibel Rating @ 7m
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
68 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Battery
Not Included (700 CCA)
Enclosure
Aluminum
Circuit Breaker Size
400 Amps
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Engine
Engine Brand
Generac 6.8 L V-10
Starting System
12v Auto Start
CC
6800 CC
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Overview
Weight
2531 Pounds
Made in USA
Yes
Consumer Warranty
2 Years
Commercial Warranty
2 Years
Product Style
Standby Generator
Product Length
115.16 Inches
Product Width
36.81 Inches
Product Height
54.84 Inches
UPC
696471610178
Product Specs
+
Specifications
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Alternator
Brushless
Auto Voltage Regulation
Yes
Rated Watts
94000 Watts
Fuel Type
Natural Gas
NG Power Capacity
94000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
Rated Amps
326 Amps
Decibel Rating @ 7m Learn More
Decibel Rating @ 7m
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
68 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Battery
Not Included (700 CCA)
Enclosure
Aluminum
Circuit Breaker Size
400 Amps
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Engine
Engine Brand
Generac 6.8 L V-10
Starting System
12v Auto Start
CC
6800 CC
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Overview
Weight
2531 Pounds
Made in USA
Yes
Consumer Warranty
2 Years
Commercial Warranty
2 Years
Product Style
Standby Generator
Product Length
115.16 Inches
Product Width
36.81 Inches
Product Height
54.84 Inches
UPC
696471610178
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
(2)
+
Search Product Q&A's Answered by Jared, the Generator Expert
icon-social-fb1
+
How much clearance is required around this unit for ventilation and service?
Frank G. 
from New York 
January 30, 2017
Answer
Per Generac: Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed in accordance with current applicable NFPA 37 and NFPA 70 standards as well as any other Federal, State and Local codes for minimum distances from other structures. Spec Sheet. I recommend checking with a local inspector to see what clearances are needed to meet code.
+
What size is the gas fitting on the generator?
John O'sullivan 
from Oregon 
October 18, 2012
Answer
The fuel fitting size is found on the spec sheet listed under the specs on the generator product page.

The spec sheet lists the fuel inlet as 1-1/4" Female NPT

100kW Spec Sheet
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Jared
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Generac Commercial Series 100kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant
Generac Commercial QT10068GNAC
+
Reset View
×
Customer Review Images